TC-55 TRANSFORMER VIBRATION TESTER
FEATURES
- The TC-55, with its small and highly sensitive sensor, is designed to detect vibration and rumbling noise of the transformer and various types of coil. The operator can set the high/low ranges of noises and retrieve an automatic evaluation of pass/fail results, shown by the OK/NG lamps. Simultaneously, the meter on the unit indicates the amount of the vibration. The (zero-cross) power can be supplied to the transformer or the test piece. With the contact output, the external control of START, OK, NG is possible.
|
SPECIFICATIONS
|
Frequency Range
|
80 Hz - 8 kHz
| |
Acceleration Range Measured
|
0.003G, 0.015G, 0.03G, 3 ranges full scale
| |
Measured Accuracy
|
Full scale, within ±5%
| |
Range Interchange Error
|
Within ± 3%
| |
External Control
|
Control in, control out,
START, RESET, NG, OK, OPE connection
| |
Test Function
|
Set the "high" and "low limit at full scale of 5% - 99% by using the digital switch.
| |
OK Test Result Display
|
Green lamp display on the front panel and connecting output terminal on the back panel.
Released by the start or reset button.
| |
NG Test Result Display
|
Red lamp display on the front panel and connecting output terminal on the back panel.
Released by the reset button.
| |
Test Output Contact
|
Each 1a contact type with the capacity of AC125V1A, or DC24V1A (no inductive load)
| |
Voltage and Current Supplies
|
AC75V - 250V, 0.05 A - 1A
| |
Supply Phase
|
ON, OFF and zero-volt voltage phase operation
| |
Power Supply
|
Single phase
| |
Power Source
|
AC voltage upon your request
| |
Power Consumption
|
Approx 30VA
| |
Operating Temperature and Humidity
|
10°C - 50°C, 5% - 95%
|
ACCESSORIES
The test unit consists of the following:
TC-55 Main Unit 1 set
VT-5100 Vibration Pickup 1 set (Attachment: Stand for pickup 2 pieces)
Pickup Cable 1 set
Power Supply Cable 1 set
Load Connector Cable (In/Out) 1 set
|
|